Mechanical Final Inspection Guide

Show the completed mechanical systems that are part of your project and demonstrate that the applicable equipment, controls, air distribution and exhaust systems are operating.

Only show what applies to your project
Keep It Simple

Show Us What's Installed and Show Us It Works.

Not every project has the same mechanical equipment or systems. Follow only the sections that apply to the permitted mechanical scope on your project.

Only complete the sections that apply to your project.

If your project does not include an air-conditioning system, ductwork, exhaust fan, dryer exhaust, range hood, fresh-air system or another item listed below, simply skip that section.

For final inspection, we need more than pictures of the equipment.

Where applicable, demonstrate that the system responds to its controls and that air is moving through representative supply and return locations.

1
Video

Show us the completed mechanical systems.

Start with a slow walkthrough of the areas included in the mechanical final.

Show whichever applies:

  • Indoor mechanical equipment
  • Outdoor mechanical equipment
  • Supply registers
  • Return-air grilles
  • Thermostats and controls
  • Exhaust or ventilation systems
  • Other mechanical equipment included in the project
2
Photo / Video
If HVAC Equipment Is Part of Your Project

Show us the mechanical equipment.

Show the completed equipment installation and enough surrounding area for the inspector to understand the location and access.

This may include:

  • Air handler
  • Furnace
  • Indoor unit
  • Outdoor condensing unit or heat pump
  • Equipment platform or support
  • Visible connections
  • Equipment labels or nameplates
  • Service access areas
3
Video / Test
If a Thermostat Controls the System

Show us the thermostat and make the system respond.

Show the thermostat powered on and demonstrate that the mechanical system responds to the control.

For the video:

  • Show the thermostat display
  • Show the current mode or setting
  • Adjust the set point or control
  • Show that the system responds

Give the system enough time to respond before ending the video.

4
Video
If the Project Has Supply Air

Show us representative supply registers.

Show supply registers in representative areas and demonstrate that air is moving while the system is operating.

Show:

  • Representative supply registers
  • Supply locations in different rooms or areas
  • Visible indication of airflow where practical
  • Any supply condition that is different from the typical installation

You do not need to record every register unless the inspector specifically requests additional evidence.

5
Photo / Video
If the Project Has Return Air

Show us the return-air locations.

Show the return-air grilles and the areas they serve.

Make sure we can see:

  • Return-air grilles
  • Return locations
  • Filters or filter access, where applicable
  • Any different or special return-air condition
6
Photo / Video
If Condensate Drainage Is Part of Your Project

Show us the condensate system.

Show the visible condensate drainage and protection associated with the installed equipment.

Show whichever applies:

  • Primary condensate drain
  • Secondary or overflow drain
  • Drain pan
  • Overflow or safety switch
  • Condensate termination
  • Traps or other visible condensate components

Show enough of the drain route and termination for the inspector to understand where the condensate goes.

7
Video / Test
If Exhaust or Ventilation Is Part of Your Project

Show us the exhaust and ventilation systems working.

Operate the exhaust or ventilation systems included in your project.

This may include:

  • Bathroom exhaust fans
  • Dryer exhaust
  • Kitchen or range exhaust
  • Fresh-air systems
  • Other mechanical ventilation systems

Show the device or grille first, then demonstrate operation where practical.

8
Photo / Video
If Applicable to Your Project

Show us disconnects, filters and accessible service items.

Show the finished mechanical components that need to remain accessible for operation or service.

This may include:

  • Equipment disconnects
  • Filter locations
  • Filter access
  • Service panels
  • Other accessible mechanical components
9
Photo / Video

Show us anything different or unusual.

If a mechanical condition is different from the typical installation, make sure your inspector can see it clearly.

  • Special mechanical equipment
  • Unusual supply or return conditions
  • Special ventilation systems
  • Different equipment types
  • Field modifications
  • Anything else included in your project that the inspector should see

Before You Submit

Only check the items that apply to your permitted mechanical scope.

  • Did you show the completed mechanical systems that are part of your project?
  • If HVAC equipment applies, did you show the equipment and visible connections?
  • If a thermostat applies, did you show it operating and demonstrate system response?
  • If supply air applies, did you show representative supply registers with the system running?
  • If return air applies, did you show the return-air locations?
  • If condensate drainage applies, did you show the drain, termination and applicable overflow protection?
  • If exhaust or ventilation applies, did you demonstrate representative operation?
  • Did you show applicable filters, disconnects and service access?
  • Did you show equipment labels or nameplates where available?
  • Did you show anything different or unusual?
You're Ready

That's It.

Submit the photos and videos for the mechanical systems that apply to your project through Permit Rockstar. Your inspector will review the completed installation and applicable operational testing against the approved project requirements.

BACK TO INSPECTION GUIDES
This guide covers typical evidence that may be needed for a mechanical final inspection. Not every item listed applies to every project. Required equipment, air distribution, controls, drainage and ventilation depend on the permitted scope, approved plans and project conditions. Your inspector may request additional evidence where needed.